Version History CANwizard 2.0.x
05.01.2012: 2.00.62
- New vendor specific signals.
16.12.2011: 2.00.61
- Migration to Visual Studio 2010.
- Changed view of port 4 on the bp308 dialog.
12.12.2011: 2.00.60
- New vendor specific signals.
22.11.2011: 2.00.59
- New vendor specific signals.
18.11.2011: 2.00.58
- Using the USB-CAN-Adaptor CANFox (Sontheim Industrielektronik GmbH) added.
- Open the log view (event monitor) takes less time.
- New vendor specific signals added.
24.10.2011: 2.00.57
- Problem regarding IXXAT VCI3 running on Win7-64-Bit fixed.
14.10.2011: 2.00.56
- New vendor specific signals.
07.10.2011: 2.00.55
- New vendor specific signals.
- Dialog view added for bp119/LMC-350.
- Print view improved.
2.00.54 vom 29.09.2011
- Minor bug fix, regarding the profile view.
- New vendor specific signals.
- Some improvements to the event log.
- New option for streaming the event log of a bp308 over the bus.
14.09.2011: 2.00.53
- Bugfix for the event log, regarding the door status information and port enumeration of generic input and output signals.
- New vendor specific signals.
31.08.2011: 2.00.52
- New vendor specific signals.
- Bugfix for outputs on CLE view on CLK-02/3.
05.08.2011: 2.00.51
- Added old product code for early bp308 boards.
03.08.2011: 2.00.50
- New vendor specific signals.
- Dialog view "Car positioning unit" updated.
02.08.2011: 2.00.49
- New vendor specific signals.
- New event monitor option "PDO" for dumping RPDOs and TPDOs.
14.07.2011: 2.00.48
- Bugfix bp308 dialog view.
- New vendor specific signals.
06.07.2011: 2.00.47
- UCP dial in method for bp308 implemented.
- Notification, if input and output functions on the same index are not equal but used.
- Fix for not responding edit field at the profile view.
22.06.2011: 2.00.46
- Receive queue for IXXAT VCI3 increased.
17.06.2011: 2.00.45
- New vendor specific signals.
- Some minor user interface changes.
07.06.2011: 2.00.44
- Safety circuit labels changed (Basic Function 0x16).
- Some improvements regarding the user interface and english translation.
- New vendor specific signals.
18.05.2011: 2.00.43
- Terminal names regarding the bp308 dialog view adapted.
- Receiving the controller data printout using block transfer without length indication implemented.
- Optional object comment feature fixed.
11.05.2011: 2.00.42
- Input focus on profile view's list view fixed.
05.05.2011: 2.00.41
- Segmented and block transfer without length indication supported.
- CAP-02 support added.
- Missing EEPROM state on CIO-01, CLK-02/3, CAP-01, CDG-01 and CSI-01 is highlighted now.
29.04.2011: 2.00.40
- Automatic user notification, if a new update is available.
- New vendor specific signals.
- Firmware updates for some of the embedded components.
21.04.2011: 2.00.39
- Vendor specific door signals added to the device view.
- After software update, the user comment notification will be removed.
19.04.2011: 2.00.38
- Bugfix regarding the CLK-02/3 dialog view.
14.04.2011: 2.00.37
- Bugxfix regarding the encoder view.
12.04.2011: 2.00.36
- Notification, if the device is not able to store the user comments.
- Faster accessing the internal object dictionary.
- Bugfix regarding the object comment feature.
08.04.2011: 2.00.35
- Storing user comments on devices supproting the object 0x2081 "User string".
- Some english resources fixed.
04.03.2011: 2.00.34
- Added user comment feature for dialog view.
- Application icon upgraded for Vista and Seven.
- Print layouts improved.
2011-03-22: 2.00.33
- User comment feature added to the profile view.
- Receive buffer increased, when using the old IXXAT VCI2 interface.
- Print layout improved, when printing the profile view.
2011-03-01: 2.00.32
- Recording of invalid SDO-telegrams as hexdump at the event monitor
- Floor selection available for vendor specific door signals
- If the profile "BÖHNKE+PARTNER" is selected, some not supported signals are hidden, at the dialog for virtual inputs and outputs.
- At the dialog view of the CDG-01 device, the main functions for "Remote Data Transmission Gateway" and the new function "CAN Modem (1..8 nodes, e.g. lift group)" is now available starting with firmware 0.9.0.
2011-01-01: 2.00.31
2010-12-09: 2.00.30
- Handling of UNIX text files fixed
2010-12-03: 2.00.29
- Wrong SDO toogle-bit abort code fixed
- Added vendor specific signals to the CBK1 view
2010-11-18: 2.00.28
- Some minor fixed at the event log
- Multiple selection assistant fixed
- On reopening the currently open file, the program will request the user, before reloading the file.
2010-11-15: 2.00.27
- Compatibility update for the CDG-01 software version 0.9.0 or higher
- Timeout for segments of a running block transfer is set to 3 seconds.
2010-11-03: 2.00.26
- The prefered language can be selected by the ActiveX dialog view for creating a summary of a configured virtual input/output.
- Clipboard support for profile listview improved
2010-10-22: 2.00.25
- Speech synthesis (Basic 0x47) added to the event monitor
- VIO-dialog: clipboard support fixed
2010-10-22: 2.00.24
- The clipboard now handles the VIO optiosn correctly at the VIO-dialog.
- Support for the object flags "refuse on download" and "refuse on scan" (CiA 306) added.
2010-10-12: 2.00.23
- Relays labels adapted to the BPC-04 component.
- If the "blink" option is not more available after changing the basic function at the VIO-dialog, the "blink"-flag will be removed out of the VIO-code, when closing the VIO-dialog by the "OK"-button. Otherwise the "blink"-flag will remain untouched.
- Fix at the encoder properties dialog, when using the offline mode.
- Added new vendor specific signal (basic 0x83) for 7-segment-displays.
2010-09-30: 2.00.22
- New attribute "IsPrinting" added to the ActiveX-Container, to signal the plugin, thatthe application creates an instance for printing or page preview only.
- Some resource fixed.
2010-09-16: 2.00.21
- Some new vendor specific signals added.
- Some ActiveX control improvements, regarding sub indexes of signal lists.
- Event monitor extensions for drive control added.
2010-08-12: 2.00.20
- Some new vendor specific signals added.
- Some resource fixed.
2010-07-30: 2.00.19
- Some user interface improvements.
- Online-Update-Assistant error handling, regarding connection timeouts, improved.
2010-07-13: 2.00.18
- The software update assistant will automatically skip nodes with the same software version, if updating a range of nodes. The assistant will check the version information as well as the timestamp of the release, if available.
- Added new vendor specific signals.
- Text view instances are now modeless, instead of modal.
- Dialog View of the CSI-01 implemented.
- Dialog item added, to select the function of an optional secondary CAN-interface plugged to the CIO-01.
2010-06-22: 2.00.17
- PFS-dialog updated.
- Dialog view of bp308 updated.
- Some resource fixed.
2010-06-17: 2.00.16
- New vendor specific Selection Call added.
2010-06-15: 2.00.15
- Fire Detector (Basiccode 0x12) added.
- Internal PFS-dialog finished.
2010-06-11: 2.00.14
- New vendor specific signals added.
- Multiple file selection for adding files to the eds-library implemented.
- Button for directly open the eds-library folder added.
- Automatic device bitmap selection on using the content of the object 0x1008. The bitmap files have to be copied to the eds-library folder. The program selects the bitmap file name that represents the beginning of the device name (0x1008) best. For example for the string "bp308 Lift Controller" (0x1008) the file "bp308.bmp" would be match and "bp308 Lift.bmp" even better.
2010-06-07: 2.00.13
- Problem of the Overlapped File I/O at the event monitor, reagrding slow solid state discs, fixed.
- Settings dialog of the event monitor provides scroll bars now, if resolution is not sufficient.
2010-06-01: 2.00.12
- Support for the new component CLK-03 added.
- Added PFE-Assistant for the new CLK-03 component.
2010-05-21: 2.00.11
- Edit fields scroll automatically horizontal inside of the profile list view.
- At the dialog for selection a serial or USB device, the "pretty names" are now added to the device name list.
- At the dialog for sending user defined SDO, the program now stores the user selected object type for each sub-index.
- Language selection added for the dialog view of the bp308 used for read the controller print-out and the menu tree print-out.
- The special function signals (basic code 0x0E) and the corresponding acknowledge signals are now tagged at the event monitor differently.
2010-04-21: 2.00.10
- Productcode of bp308 changed.
- Ressources fixed.
2010-04-16: 2.00.09
- Problem that may occur on saving on network devices fixed.
- The event monitor handles a floor byte value of 255 as "all floors" on outputs and "reserved" on inputs and calls.
2010-03-31: 2.00.08
- Software update of bus components enabled, when running the service version.
- New button "View" for directly opening the event monitor's log file.
- Logging of Error Frames, running on can-adapters supporting this feature (currently IXXAT-VCI3 only).
- New vendor specific signals added.
2010-03-29: 2.00.07
- I/O configuration and print layout improved.
- User interface improvements.
2010-03-23: 2.00.06
- The "passive Mode" by using IXXAT and SYSTEC-Adaptors supported now.
- Access to the IXXAT-VCI3-Interface accelerated.
2010-03-19: 2.00.05
- New command "Request all special inputs" shown at the event monitor.
- Door command 0xF ("Do not care / take no action") hidden for door B/C/D.
- Detail improvements
2010-03-11: 2.00.04
- Recording of EMCY messages implemented.
- Error found in PEAK implementation (USB/PCI/DONGLE) fixed.
2010-02-26: 2.00.03
- New vendor specific signals (153, ..).
- Optional enabling and disabling of vendor (Böpa) specific input and output signals.
- Added print functionality to the CLK-02 extension view.
2010-02-10: 2.00.02
- New vendor specific signals (term. 121..123, 132..134, 190..199)
- Assistant for CAP-01 node id enumeration, supported by CAP-01 firmware version 1.0 (02-2010) or higher.
- On creating the summary description of calls, "reserved" is added instead of "all floors", if the floor byte is 255.
2010-01-13: 2.00.01
- Problem at the input/output dialog view of the bp308 (BPC-04) fixed.
- New vendor specific signals (term.20, term. 313) of the bp308 added.
2009-12-10: 2.00.00
- Dialog view for bp308 lift controller approved.
- New flag "DLG_FLAG_VENDOR_SIGNALS_ONLY" for the ActiveX-container implemented, used to force the dialog "virtual inputs/outputs" to show only the basic/subcode pairs, referenced by a pointer.
Documentation to the ActiveX-container updated.
- The event monitor now tracks the cabin weight, if provides as PDO.
"Generic Input" / "Generic Output" view fixed.
Support for the new objects 0x6001 (Lift number), 0x6002 (Floor number) and 0x6003 (Car door number) implemented.
- Dialog for basic data of the CBK-01 implemented.
If the port mode on a CLK-02 or CIO-01 is activated, the user has the possibility to change back not the I/O-view anyhow.
- New option "Save object content as..." placed at the context menu of the profile view.
Automatic try of a block-transfer-download starting at a file size of 512 Bytes. Fallback to segemented transfer ("normal transfer") on SDO_ERR_CS_INVALID.
- Software update assistant recognizes program version of bp308 file images.